Hi all,

I have one query about the charpy impact test. Do the stainless steel (P-No.8), Duplex & Super Duplex (P-No.10H) required charpy impact test or not? If yes, what condition which I need to consider when doing the charpy impact test and where can I refer?

Thank you,

Regards,
Shukri



No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...