Re: [MW:6680] RT report for coded vessel

In no case the AI has to stamp any NDE report.
According to UG-90 (c)(1)(i) he has to verify that required NDE has been performed and that results are acceptable. Evidence for this verification could be signing of the RT reports by the A.I

Dr. G. Dilintas - Authorized Inspector Supervisor
I&F Regional Technical Manager
Bureau Veritas Piraeus - Greece
Tel: +30 210 40 63 113/4
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
Inactive hide details for skrie85 <skrie85@yahoo.com>skrie85 <skrie85@yahoo.com>


          skrie85 <skrie85@yahoo.com>
          Sent by: materials-welding@googlegroups.com

          24/08/2010 10:48

          Please respond to
          materials-welding@googlegroups.com

To

materials-welding@googlegroups.com

cc


Subject

[MW:6677] RT report for coded vessel

Ref


For CODED vessel (U-Stamp), does the RT film and RT report for nozzle less than 10" no need A.I to review or sign?

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...