Saturday, January 8, 2011

[MW:9144] RE: 9141] inspection of existing Offshore platform

Hi Gobi,
 
These standards/rules explicitly apply for offshore structures where DNV rules, codes, design guidelines and inspection/certification is applicable.Many of the standards are free downloads and are excellent resources for knowledgebase.
 
The other resources would be:-
  1. API RP 2A-WSD Recommended Practice for Planning, Designing and Constructing Fixed Offshore Platforms -
  2. API RECOMMENDED PRACTICE 2X- Recommended Practice for Ultrasonic And Magnetic Examination of Offshore Structural Fabrication and Guidelines for Qualification of Technicians

Offshore platforms, especially, design,fabrication ,inspection would involve more than one codes. In order to get a fair idea of all the aspects, the above API RP's would be quite helpful.
 
Best of luck and feel free to throw interesting queries.
 
Thanks
 
 
Pradip Goswami,P.Eng,IWE.
Welding & Metallurgical Specialist & Consultant
Email-pgoswami@sympatico.ca,
 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Govindarajan Shanmugam
Sent: Friday, January 07, 2011 7:03 AM
To: materials-welding
Subject: [MW:9141] inspection of existing Offshore platform

Hai all,
 
I want to know about inspection of existing Offshore platform. It would be greatful if anyone describes the important points to be considered/verified. And also suggest me any code/standard/specifacation/procedure/inspection program/inspection plan/ITP is available for the same.
 
Thanks in advance.--

With Regards.
Govi

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...