I am not agree for the repair with R stamp as these exchanger are not commissioned and not yet installed so will not comes in juridiction of R stamp
This can be repaired and re tested with AI with approval of repair procedure

Also raise NCR for end user confirmation as this is major NCR and definetely end user approval is required with repair procedure approval

Abhijit

Sent from my iPhone

On 2011 जानेवारी 14, at 08:35, Fred Majdnia <FMajdnia@technip.com> wrote:


Dear  Karandish

 

You can accept the repair procedure with the following approach:

 

  • Get A.I. approval of the written repair procedure if the Item is Code stamped. The repair work shall also be done by a R-stamp holder.
  • Cut the damaged area using mechanical means( No flame cutting to be used)
  • Pull out the tube Bundle for inspection ( it is unlikely to have tubes damaged)
  • Weld the insert patch with round corners or circular shape
  • WPS/PQR should have been qualified with double PWHT meeting all requirements of SA387 -11 CL2+S5
  • Perform RT and UT on the weld
  • Grind flush the weld from inside
  • Perform Pressure Test
  • Insert the Bundle and prepare to close it up
  • Fill R1 form if the Item was code stamped. To be signed by stamp holder and A.I – Install a new R-name plate if the insert patch is done. If Nozzle is used then R-name plate may not be required if A.I agrees and accepts the repair as a routine repair per NB-23.
  • No need to do leak test, if the tubes were not damaged.

 

 

Please note that a Nozzle of 4" or 5" can be welded instead of the insert patch if the proposal and design calculation accepted by Client ( end user).

 

Good luck

Regards

 

 

-----materials-welding@googlegroups.com wrote: -----

To: materials-welding@googlegroups.com
From: AA karandish <aa.karandish@yahoo.com>
Sent by: materials-welding@googlegroups.com
Date: 01/13/2011 12:29AM
Subject: [MW:9206] HEAT EXCHANGE ACCIDENT

Dear all,

 

My company has an EPCC (Engineering, Procurement, Construction and Commissioning) contract for an Ammonia plant with a contractor. During the transportation a shell and tube heat exchanger is faced to an accident which causes a severe damage on its shell side. Major defect has the size of 50 x 50 CM and bighted inside approx. 4 cm (like a bowel but not so smooth).

Repair procedure submitted by the contractor is divided in two sections as follows:

 

: Section 1

1-      Performing the hydrostatic test on shell and tube side.

2-      Performing the MT and UT on dented areas.

3-      Performing the hardness test on all damaged joints (base metal, weld metal and HAZ).

4-      If the mentioned test on this section is approved then heat exchanger is ready for shipment to site

 

 

: section 2

     If the mentioned test in section "A" do not approved then:

1- Damaged tubes shall be replaced.

2- Dented areas on shell shall be cut and patched with the same material.

3- Performing the UT and MT on new weld seams.

4- Performing the hydro-test on shell and tube side.

 

Specification of this heat exchanger is as follow:

·         Size: 1500 ID x 7900 L

·         Type: NEN horizontal

·         Code : ASME SEC viii DIV 1 & TEMA CLASS R

·         Shell and tube side design pressure: 180 barg

·         Shell side design temperature: 240 deg C

·         Tube side design temperature: 335 deg C

·         MDMT: -14 deg C

·         Shell and tube side are in H2 service

·         Shell material: SA-387-11 CL2+S5

·         Channel & tube-sheet material:SA-336-F11 CL2+S13

·         Tube material: SA-213T11

·         PWHT: already done after fabrication.

 

   My request from you:

a-      Please check the submitted procedure for its adequacy in detecting the possible damage/ and have your comment for new test if any.

b-      By my opinion in any case a window on shell side shall be cut to check the condition of heat exchanger tubes and renew the dented area.

c-      Since the heat exchanger is already PWH treated after the fabrication, please let me know your opinion regarding the second PWHT after repair and its effect on properties of base metal.

 

Thank you for your prompt attention,

 

 

 

 



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


    This email and any attached files ("Message") may contain confidential and/or privileged information. It is intended solely for the addressee(s). If you receive this Message in error, inform the sender by reply email, delete the Message and destroy any printed copy. Any unauthorized use, distribution, or copying of this Message or any part thereof is prohibited. Emails are susceptible to alteration. Neither Technip nor any of its affiliates shall be liable for the Message if altered or falsified nor shall they be liable for any damage caused by any virus that might be transmitted with this Message. 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...