Hii ,
 
A per  my practical experience ,It was acceptable now becuase we can not do anything unless we cut the spool piece and rotate then re weld ......with elbow ....but present situation  is It has been already welded .and also it was duplex material ...So
 
If Client is favour on this situation ,please take the hardness at HAZ area of bothsides and go for 100% RT .
 
But fitter was done mistakenly welded...e when he was fit up done with pipe to elbow .He should have rotate the pipe before the fit up ....
 
This is my concern ...
 
Thank you
 
Suresh

On Wed, Jan 26, 2011 at 5:15 PM, Elshan Feyzullayev <elshan_f@hotmail.com> wrote:
Dear team members,

The material spec is super duplex UNS 32760.
Construction code is ASME B31.3.
Operating pressure is 16Bar.
We have bought the elbows and pipe material with the logitudinal weld seam.
During the fabrication we have faced with the problem on elbow to elbow and pipe to elbow welding. The problem is the manufacture weld seams are in the same line as indicated in the attached photos. Is it acceptable?

Please share your experiences.

best regards,
Elshan.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Thanks  & Best Regards,

Suresh

Mobile No: 91-92 92 905 905

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...