Re: [MW:9504] impact test specimens


both are u are true...but need to combine together


12 o'clock (weld metal, FL and FL+2, FL+5), 3 o'clock(weld metal, FL and FL+2, FL+5) and 6 o' clock (weld metal, FL and FL+2, FL+5)


"manpreet " <manpreetsin88@rediffmail.com>
Sent by: materials-welding@googlegroups.com

01/27/2011 11:07 AM

Please respond to
materials-welding@googlegroups.com

To
"materials-welding " <materials-welding@googlegroups.com>
cc
Subject
Re: [MW:9501] impact test specimens





Dear Reddy,

Your spec means, for weld metal, FL and FL+2, impact test shall be carried out for top, centre and root region, each of the test would require 3 specimens.

let me know if you could interpret this correctly or else I would explain with detailed sketch.

Regards
Manpreet Singh



On Wed, 26 Jan 2011 13:29:53 +0530 VENKATA SWAMI REDDY KARRI wrote
>

Dear All,
 
Acording to our spec " Impact test sets shall be taken from 12 o'clock, 3 o'clock and 6 o' clock at
centre of weld
fusion line
+2mm from fusion line in the parent metal
 
Each test set shall include 3 specimens"
 
 
I have a doub't that we have to take the specimens  ex:   for centre of the weld 3specimens need to take at 12 o' clock  or 1 from 12,3and 6o'clock respectivly
 


>--
>

 

Best Regards,

K.V.S.Reddy,
>Q.C.Inspector(Piping&Welding),
>BS-132 Project,
>SKEC Eng& Con Ltd.,
>Postbox no-55653,
>Sabahiya-54567,
>Kuwait.
>kvsreddy777@gmail.com,karryswamireddy@yahoo.com,
>Ph:00965-94414396.

PleaseSave a tree. Don't print this e-mail unless it's really necessary

>

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

This electronic mail content and any accompanying attachments ("the Message") is intended only for the named addressee ("the Recipient") and may contain information that is confidential, privileged and/or proprietary to the Sime Darby group of companies ("Sime Darby") and/or protected under applicable laws. If you are not the intended Recipient, you are strictly prohibited from using, disseminating, forwarding and/or printing the Message. Please notify the sender immediately by return e-mail and permanently delete all copies of the Message. Sime Darby disclaims all liability for any error, loss or damage arising from the Message being infected by computer virus or other malicious software. Any views and/or opinions expressed in the Message are solely those of the author's and do not necessarily represent those of Sime Darby's.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...