Tuesday, April 9, 2013

Re: [MW:17321] Re: What are the criteria to select Stub in or Stub on for Branch connection in Piping?

Hi.
Other criteria may be: stub in for heather pipe in not operation and stub on for heather pipe in operation.

Agustin Jimenez
Equipment static specialist.
Enviado desde mi BlackBerry de Movistar

From: vineet kumar <vineet.rdb@gmail.com>
Sender: materials-welding@googlegroups.com
Date: Mon, 8 Apr 2013 22:35:44 -0700 (PDT)
To: <materials-welding@googlegroups.com>
ReplyTo: materials-welding@googlegroups.com
Subject: [MW:17318] Re: What are the criteria to select Stub in or Stub on for Branch connection in Piping?

Dear,

For "stub in," the stub or branch pipe extends to the inside of the main pipe. The hole in the main pipe is (usually) beveled to allow for a full-penetration weld. For "stub on," the stub extends only to the outside of the main pipe. The stub may be beveled, but if not only a fillet weld can be done. "Stub in" is generally stronger, and often much stronger.

Regards,
Vineet

On Monday, April 8, 2013 3:19:12 PM UTC+5:30, PK wrote:
Dear Experts,

What are the criteria to select Stub in or Stub on for Branch connection in Piping?

(Or)

How to choose Stub in or Stub on for Branch connection in Piping?

Thank you,

Pkm..

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...