Sunday, July 31, 2016

Re: [MW:25175] how to calculate hydrostatic head

P=qgh
P=pressure
q= densiry of water 1000kg/m3
g= 9.81m/s2
H=head suppose 10 m

P= 98100N/m2
P=1.013kg/cm2

Where 1 N= 1 kg.m/s2


Hence @ 10 m height we consider pressure 1 kg/cm2.

Regards
Kunal Patel

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/66fc2fae-3bec-44f4-adef-43d27ac30aad%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25174] Multiple welders can weld in a single production joint?

Dear Mr.Jijilal,

The pdf attachment  is production weld mockups for Procedure and performance qualification.

The production weld is the first joint  which  a welder welds after the qualification of his welder qualification test specimen.

Regards,

Hareesh K V


On 31 Jul 2016 4:08 p.m., "JIJILAL K M" <jijilalkm2@gmail.com> wrote:
Please refer the attachment 

Best Regards,

JIJILAL K.M. 
QA/QC Manager,
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand
#096 786 0129


On 29 July 2016 at 17:11, Rajakani A <araja192@gmail.com> wrote:
Dear friends,


 Can multiple welders weld in a single production joint in same process and position?

Kindly clarify me with reference ASME standards if any.

Regards,

Rajakani A,
L&T Construction,
Surat.
+91-7874201744.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHiUTkbai5CSKpgXNicHLU8w4dsMo2TFqxj4_R2E0u7vzA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAM3LgAUdvVVYeK6qQ2SOEJsoLWjUhmCEPpkNgYifP_d8DvxEAQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25173] RE: 24605] 3/4" Tube weld RT

Dear,

You can use Selenium-75 with slow film for better results.

Thanks & Regards
Venkat
QA/QC Inspector
Oryx Piping
UAE

On Thu, Apr 7, 2016 at 6:58 PM, Mohd Siraj <mohd52100@gmail.com> wrote:
You can use x rays with slow film for.better result.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4fb26d98-e3e6-4548-aca0-89d5915665ab%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHAXWsMwn84125_JnkyZHrkP_7FC2iaes%2BmGFW0yPTooUmcDkQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

RE: [MW:25171] Multiple welders can weld in a single production joint?

In pipeline welding practice it is normal to have different welders working on opposite sides of the pipe for all diameters.

 

Alan Denney

AKD Materials Consulting Ltd

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Hareesh K V
Sent: 30 July 2016 17:08
To: materials-welding@googlegroups.com
Subject: Re: [MW:25169] Multiple welders can weld in a single production joint?

 

Dear friend,

 

This can be done as there is no code restrictions. If the joint is failed all the welders are considered to be failed.

 

For bigger diameter pipes say, 60" which is usually welded by more than  one welder this can be accepted.

 

The concept of the production weld is to understand the ability of the welder in a real job situation. So on that basis try to avoid using multiple welders in one production joint.

 

Regards,

 

Hareesh K V 

 

 

 

Sent from my Samsung Galaxy smartphone.

 

-------- Original message --------

From: Rajakani A <araja192@gmail.com>

Date: 29/07/2016 3:41 p.m. (GMT+05:30)

To: Materials & Welding <materials-welding@googlegroups.com>

Subject: [MW:25157] Multiple welders can weld in a single production joint?

 

Dear friends,

 

 

 Can multiple welders weld in a single production joint in same process and position?

 

Kindly clarify me with reference ASME standards if any.

 

Regards,

 

Rajakani A,

L&T Construction,

Surat.

+91-7874201744.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/dldxs1hjoqq88m8dlohuim6f.1469894902247%40email.android.com.
For more options, visit https://groups.google.com/d/optout.

Saturday, July 30, 2016

Re: [MW:25170] Multiple welders can weld in a single production joint?

If they are qualified yes. It happens very often when ‎a welder performs root with GTAW and then an other completes with SMAW

Sent from my BlackBerry 10 smartphone.
From: Rajakani A
Sent: Σάββατο, 30 Ιουλίου 2016 - 09:38
To: Materials & Welding
Reply To: materials-welding@googlegroups.com
Subject: [MW:25157] Multiple welders can weld in a single production joint?

Dear friends,


 Can multiple welders weld in a single production joint in same process and position?

Kindly clarify me with reference ASME standards if any.

Regards,

Rajakani A,
L&T Construction,
Surat.
+91-7874201744.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.


Re: [MW:25169] Multiple welders can weld in a single production joint?

Dear friend,

This can be done as there is no code restrictions. If the joint is failed all the welders are considered to be failed.

For bigger diameter pipes say, 60" which is usually welded by more than  one welder this can be accepted.

The concept of the production weld is to understand the ability of the welder in a real job situation. So on that basis try to avoid using multiple welders in one production joint.

Regards,

Hareesh K V 



Sent from my Samsung Galaxy smartphone.

-------- Original message --------
From: Rajakani A <araja192@gmail.com>
Date: 29/07/2016 3:41 p.m. (GMT+05:30)
To: Materials & Welding <materials-welding@googlegroups.com>
Subject: [MW:25157] Multiple welders can weld in a single production joint?

Dear friends,


 Can multiple welders weld in a single production joint in same process and position?

Kindly clarify me with reference ASME standards if any.

Regards,

Rajakani A,
L&T Construction,
Surat.
+91-7874201744.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25168] RF pad clashing with circumferential pipe weld joints

Dear Sir, 

Take RT/UT of that area (consider the weld area of fillet weld for RF pad also)

After getting it cleared in RT/UT; flush grind the area and do the fitup of the RF pad.

Some specification insists to do DPT after flush grinding (Even after acceptance of RT/UT); before fitup of RF pad.

Regards,

Hareesh K V
+91-8547859202



Sent from my Samsung Galaxy smartphone.

-------- Original message --------
From: JIJILAL K M <jijilalkm2@gmail.com>
Date: 30/07/2016 2:23 p.m. (GMT+05:30)
To: materials-welding@googlegroups.com
Subject: [MW:25163] RF pad clashing with circumferential pipe weld joints

Dear Experts,

Refer to subject line and attachment , An RF pad is coming closely  with the circumferential weld of a lateral Tee.

Please advice how to resolve it. Code is ASME B 31.1.



Best Regards,

JIJILAL K.M. 
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHjWb9xPp0KfV_gBBZh2Xu3Cm33QVuu8TjPAVW_SFmBUsA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25167] Multiple welders can weld in a single production joint?

Dear Rajakani...
It is allowed as there is no restriction from Code..Code is generally having restrictions...

hope to have your understanding..

Aly

On Fri, Jul 29, 2016 at 2:11 PM, Rajakani A <araja192@gmail.com> wrote:
Dear friends,


 Can multiple welders weld in a single production joint in same process and position?

Kindly clarify me with reference ASME standards if any.

Regards,

Rajakani A,
L&T Construction,
Surat.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOenW4i9dDNQsUe1%2B9YyvMyYsv4TaEMkUDLERT7dBz8ROFmD1Q%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25171] Multiple welders can weld in a single production joint?

Please refer the attachment 

Best Regards,

JIJILAL K.M. 
QA/QC Manager,
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand
#096 786 0129


On 29 July 2016 at 17:11, Rajakani A <araja192@gmail.com> wrote:
Dear friends,


 Can multiple welders weld in a single production joint in same process and position?

Kindly clarify me with reference ASME standards if any.

Regards,

Rajakani A,
L&T Construction,
Surat.
+91-7874201744.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHiUTkbai5CSKpgXNicHLU8w4dsMo2TFqxj4_R2E0u7vzA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25166] Re: Tack welder qualification

ASME  VIII says tack welders shall be qualified.
Sec. IX not specifically mentioned.

So  both in refinery & power plant , as per ASME IX , QW-461.9   we followed 5F position (pipe to plate 45 degree  inclined) to qualify tack welders.

Best Regards,

JIJILAL K.M. 
QA/QC Manager,
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand
#096 786 0129


On 29 July 2016 at 21:10, César Alexis Viteri Pérez <alexis_viteri@hotmail.com> wrote:
Be sure that tack welders dont open arc out if bevel.


Date: Thu, 28 Jul 2016 21:05:20 +0300
Subject: Re: [MW:25156] Re: Tack welder qualification
From: dilintas@gmail.com
To: materials-welding@googlegroups.com


...if they remain in place...

Sent from my BlackBerry 10 smartphone.
From: anthony chundal
Sent: Πέμπτη, 28 Ιουλίου 2016 - 13:04
To: Materials & Welding
Subject: [MW:25155] Re: Tack welder qualification


Dear Sam,

As per ASME Sec VIII-Div-1, UW-31(c), tack welders need to be qualified.

Regards,
Anthony.


On Tuesday, December 13, 2011 at 8:48:37 PM UTC+4, samshuddin k wrote:
Dear Experts
There is any clause in ASME Sec. IX for tack welder qualification.
Which Code explains tack welder qualification for piping
regards
Samshuddin.K

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/cc0d08ba-e64a-49a5-9402-5354a48c9a48%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/20160728180520.6713423.18949.3894%40gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/BLU183-W15A51C161BD8FC45EFA3828F010%40phx.gbl.

For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHggn7m8YPraKd08aZ-M3aeuLvV5EwVn0LVmLBnhzE0p5w%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25165] RF pad clashing with circumferential pipe weld joints

take RT on fouling area and extra area and u can close it 

THANKS & BEST REGARDS,
KG.PANDITHAN, IWE,  AWS-CWI, CSWIP 3.1,
CONSULTANT-WELDING & QUALITY
Mobile no: +919940739349

On Sat, Jul 30, 2016 at 2:23 PM, JIJILAL K M <jijilalkm2@gmail.com> wrote:
Dear Experts,

Refer to subject line and attachment , An RF pad is coming closely  with the circumferential weld of a lateral Tee.

Please advice how to resolve it. Code is ASME B 31.1.



Best Regards,

JIJILAL K.M. 
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHjWb9xPp0KfV_gBBZh2Xu3Cm33QVuu8TjPAVW_SFmBUsA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAJzm4eNKBVJ8KEBvZ7VR3jQUvWWKtD95Tj%2B%2Bm_10f8DTQVMF3A%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25163] Full form of SFA


Dear Raneesh,

In my info. it is  'Specification for Filler metal Analysis'



Best Regards,

JIJILAL K.M. 
QA/QC Manager,
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand
#096 786 0129


On 30 July 2016 at 09:58, Raneesh.PK <pkraneesh@gmail.com> wrote:

Dear Expert,

Please help me regarding below full form,

SFA 5.1 (aws classification of carbon steel electrode).....what does mean of SFA????

Regards,

Raneesh.ok
Sr.Qc engineer-kochi refinery
Cswip 3.1 & ASNT

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAGRQ%2BmX-pFVRpFAYcvBmrSW%2Bv3n3z4fq2sctdDEuJvfv2aFwog%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHj%3D_ko_dy-zLzKO6C71BfQw%3DxQK8KEyXAE6q4pgQ5WMWA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

[MW:25163] RF pad clashing with circumferential pipe weld joints

Dear Experts,

Refer to subject line and attachment , An RF pad is coming closely  with the circumferential weld of a lateral Tee.

Please advice how to resolve it. Code is ASME B 31.1.



Best Regards,

JIJILAL K.M. 
Thai Jurong Engineering Ltd,
KCE SPP Project,Thailand


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHjWb9xPp0KfV_gBBZh2Xu3Cm33QVuu8TjPAVW_SFmBUsA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25162] Full form of SFA

Standard Filler analysis

On Sat, Jul 30, 2016 at 7:58 AM, Raneesh.PK <pkraneesh@gmail.com> wrote:

Dear Expert,

Please help me regarding below full form,

SFA 5.1 (aws classification of carbon steel electrode).....what does mean of SFA????

Regards,

Raneesh.ok
Sr.Qc engineer-kochi refinery
Cswip 3.1 & ASNT

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAGRQ%2BmX-pFVRpFAYcvBmrSW%2Bv3n3z4fq2sctdDEuJvfv2aFwog%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAB%3DAs8kNjpPs%3DYfsEZTzWERyunusBpLwsqVAx8idv-K5ObfXvg%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25161] Full form of SFA

Dear Raneesh

SFA is SPECIFICATION FOR FILLER METAL ANALYSIS

Regards,
Aby

On Sat, Jul 30, 2016 at 6:58 AM, Raneesh.PK <pkraneesh@gmail.com> wrote:

Dear Expert,

Please help me regarding below full form,

SFA 5.1 (aws classification of carbon steel electrode).....what does mean of SFA????

Regards,

Raneesh.ok
Sr.Qc engineer-kochi refinery
Cswip 3.1 & ASNT

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAGRQ%2BmX-pFVRpFAYcvBmrSW%2Bv3n3z4fq2sctdDEuJvfv2aFwog%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CACdTRdwMpeHR0LxQVmLY9X42an_JfGwbymMJ_CAQjZ0x8rsDcQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25160] PWHT

Mr Jose is correct

With Kind Regards

P Govindan



On Wed, Jul 27, 2016 at 11:23 PM, José Juan Jiménez Alejandro <jjjimeneza@gmail.com> wrote:
This information is gold, few people know.
Regards!.

2016-07-27 1:49 GMT-05:00 Krisanu Bhunia <krisanu.bunty@gmail.com>:
thank you, A537 CL1 is P1 marital but which thickness can do welding and which clause it is mention     

On Tue, Jul 26, 2016 at 8:45 PM, José Juan Jiménez Alejandro <jjjimeneza@gmail.com> wrote:
BPVC ASME Section VIII Div 1, allows welding after the PWHT, but only for materials P1 and P3 and only certain thickness, but remember that this code is only for new equipment, not for equipment being repaired, if this is your building code ahead !.

2016-07-25 3:41 GMT-05:00 ishwar kumar <ish8623@gmail.com>:


Sent from my iPhone

On 15-Jul-2016, at 3:11 AM, Krisanu Bhunia <krisanu.bunty@gmail.com> wrote:

Dear sir,

In clean out door in tank we found welding not sufficient after PWHT.(A 537 CL1)
SO, now need to welding again . PWHT again doing or can avoid it by which code ?

Regards
krisanu bhunia
 

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAMZth3qmH8a3w0Efd96-M12HsymvR61YRPz18j1nOFpdZME9PQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4797E08A-DC0C-48F2-924D-5F0F5CA2C326%40gmail.com.
For more options, visit https://groups.google.com/d/optout.



--

Ing. Jose Juan Jimenez Alejandro

Cel. 8116171750

Skype: jjjimeneza

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to a topic in the Google Groups "Materials & Welding" group.
To unsubscribe from this topic, visit https://groups.google.com/d/topic/materials-welding/uHRzkNOaGNw/unsubscribe.
To unsubscribe from this group and all its topics, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAO5ZurK%3DsL48-4rGdYMqNxnQNa7ZKXYkqoiE7rMePC7mpAu48w%40mail.gmail.com.

For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAMZth3r9R93LbPOOBr%2B1cQVttdywdCK36QHp3Upjh%2B2SRrt4yQ%40mail.gmail.com.

For more options, visit https://groups.google.com/d/optout.



--

Ing. Jose Juan Jimenez Alejandro

Cel. 8116171750

Skype: jjjimeneza

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAO5Zur%2BjbHf849DKFr%2BA_H6Ye2BsercDSdxh3H0w4id8C35xMA%40mail.gmail.com.

For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANiuf9cd%3DtVmBffbRD_s4wtstSL0va-vVDKohtNDAGR5B2Ec%3Dg%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

[MW:25157] Full form of SFA

Dear Expert,

Please help me regarding below full form,

SFA 5.1 (aws classification of carbon steel electrode).....what does mean of SFA????

Regards,

Raneesh.ok
Sr.Qc engineer-kochi refinery
Cswip 3.1 & ASNT

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAGRQ%2BmX-pFVRpFAYcvBmrSW%2Bv3n3z4fq2sctdDEuJvfv2aFwog%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Friday, July 29, 2016

RE: [MW:25157] Re: Tack welder qualification

Be sure that tack welders dont open arc out if bevel.


Date: Thu, 28 Jul 2016 21:05:20 +0300
Subject: Re: [MW:25156] Re: Tack welder qualification
From: dilintas@gmail.com
To: materials-welding@googlegroups.com

...if they remain in place...

Sent from my BlackBerry 10 smartphone.
From: anthony chundal
Sent: Πέμπτη, 28 Ιουλίου 2016 - 13:04
To: Materials & Welding
Reply To: materials-welding@googlegroups.com
Subject: [MW:25155] Re: Tack welder qualification


Dear Sam,

As per ASME Sec VIII-Div-1, UW-31(c), tack welders need to be qualified.

Regards,
Anthony.


On Tuesday, December 13, 2011 at 8:48:37 PM UTC+4, samshuddin k wrote:
Dear Experts
There is any clause in ASME Sec. IX for tack welder qualification.
Which Code explains tack welder qualification for piping
regards
Samshuddin.K

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/cc0d08ba-e64a-49a5-9402-5354a48c9a48%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/20160728180520.6713423.18949.3894%40gmail.com.
For more options, visit https://groups.google.com/d/optout.

[MW:25157] Multiple welders can weld in a single production joint?

Dear friends,


 Can multiple welders weld in a single production joint in same process and position?

Kindly clarify me with reference ASME standards if any.

Regards,

Rajakani A,
L&T Construction,
Surat.
+91-7874201744.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4733b8e2-5b61-4e6d-9838-6baa0baadd77%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Thursday, July 28, 2016

Re: [MW:25156] Re: Tack welder qualification

...if they remain in place...

Sent from my BlackBerry 10 smartphone.
From: anthony chundal
Sent: Πέμπτη, 28 Ιουλίου 2016 - 13:04
To: Materials & Welding
Reply To: materials-welding@googlegroups.com
Subject: [MW:25155] Re: Tack welder qualification


Dear Sam,

As per ASME Sec VIII-Div-1, UW-31(c), tack welders need to be qualified.

Regards,
Anthony.


On Tuesday, December 13, 2011 at 8:48:37 PM UTC+4, samshuddin k wrote:
Dear Experts
There is any clause in ASME Sec. IX for tack welder qualification.
Which Code explains tack welder qualification for piping
regards
Samshuddin.K

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/cc0d08ba-e64a-49a5-9402-5354a48c9a48%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Re: [MW:25154] use of PN16 flanges dimensions are as per EN 1092-1 for asme div-1

If there the flange is not in accordance with one of the standards approved by the Code then calculation according App 2 us a must

Sent from my BlackBerry 10 smartphone.
From: Hemant W Joshi
Sent: Πέμπτη, 28 Ιουλίου 2016 - 08:51
To: materials-welding@googlegroups.com
Reply To: materials-welding@googlegroups.com
Subject: RE: [MW:25152] use of PN16 flanges dimensions are as per EN 1092-1 for asme div-1

What is the type of flange, size  in question?

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of anthony chundal
Sent: Wednesday, July 27, 2016 7:07 PM
To: Materials & Welding
Subject: [MW:25151] use of PN16 flanges dimensions are as per EN 1092-1 for asme div-1

 

Please advice whether we can use PN16 flanges dimensions are as per EN 1092-1 without providing any calculations as per appendix -2, for ASME Div-1 pressure vessel, material specification is SA105,

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/6a44a704-4339-4191-a555-1ff396a4ab96%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.


----------------------------------------------------------------------------------------------------------
Information transmitted by this E-MAIL is intended only for the use of the addressee(s) and contains information that is privileged, confidential or exempt from disclosure under applicable law. If you are not the intended recipient or it appears that this mail has been forwarded to you without proper authority, you are notified that any use or dissemination and or copying of this email in any manner is strictly prohibited and you are requested to delete this e-mail immediately.
Communicating through e-mail is not secure and capable of interception and delays. Any one communicating with TATA Consulting Engineers Ltd., and / or its subsidiaries or associates or group companies by e-mail accepts the risks involved and their consequences.
While this e-mail has been checked for all known viruses, the addressee should also scan for viruses and notify the originator of e-mail.
---------------------------------------------------------------------------------------------------------

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/c8097cf1b9fb4aa3b4f647bc8abd542c%40MUMEXG02.TCE.COM.
For more options, visit https://groups.google.com/d/optout.

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.